An aluminium tripod and winch stand over an open street manhole, with the retrieval line clipped to the back D-ring of a harnessed entrant while an attendant in a hi-vis vest stands by with a gas detector.
Fall Protection

Confined Space Equipment: A Checklist for Safe Entry, Retrieval and Rescue

9 min read

Short answer: Confined space equipment covers five jobs: testing the air with a calibrated gas detector, ventilating the space, getting workers in and out with a tripod or davit, winch and retrieval harness, keeping the attendant in contact, and rescuing without sending anyone else in. Ontario's O. Reg. 632/05 requires the equipment in your plan to be inspected and ready.

Confined spaces kill quietly and they kill rescuers. The Canadian Centre for Occupational Health and Safety (CCOHS) estimates that about 60% of confined-space fatalities are would-be rescuers. Poor air, engulfment, moving parts and a hard way out all make an ordinary task more dangerous inside a tank, vault, pit or manhole. The right equipment, chosen for the specific space and checked before every entry, is what lets a crew test, enter, work and get out without improvising.

This guide is about the equipment. For the step-by-step on air testing, entry permits and rescue planning, read our companion guide, Before anyone goes in: confined-space air testing and rescue planning.

What the rules expect from your equipment

Every Canadian jurisdiction has confined-space rules, and the details differ. In Ontario, O. Reg. 632/05 is specific about equipment:

  • Rescue equipment identified in the plan must be readily available, appropriate for entry into that space, and inspected by a competent person as often as needed, with each inspection recorded (s. 12).
  • The employer must set up methods of communication suited to the hazards so workers inside can reach the attendant (s. 12(3)). The attendant needs a device for summoning rescue (s. 15).
  • Each entrant gets adequate PPE, clothing and devices under the plan (s. 13), and there must be an adequate means of entering and exiting (s. 16).
  • Air testing must use calibrated instruments in good working order that suit the hazards identified (s. 18).
  • If mechanical ventilation is needed to keep the air acceptable, there must also be a warning system and exit procedure in case the ventilation fails (s. 20).
  • The entry permit lists the equipment required for entry and rescue and confirms it's in good working order (s. 10).

The national consensus standard, CSA Z1006:23, Management of work in confined spaces (third edition, 2023), also covers PPE and other equipment, remote monitoring and rescue planning as part of a confined space management program. It's voluntary unless your jurisdiction references it.

An aluminium tripod and winch stand over an open street manhole, with the retrieval line clipped to the back D-ring of a harnessed entrant while an attendant in a hi-vis vest stands by with a gas detector.

1. Gas detection: test before entry and keep monitoring

Most confined-space deaths start with the air. Under O. Reg. 632/05, acceptable oxygen is at least 19.5% and not more than 23% by volume, and flammable gas limits are set as a percentage of the lower explosive limit (LEL) depending on the work.

  • A portable multi-gas detector that reads oxygen, LEL and the toxic gases your assessment identified, commonly carbon monoxide (CO) and hydrogen sulphide (H₂S).
  • A sampling pump and probe or tubing so the space can be tested at different levels from outside before anyone enters. Gases can layer: some sit low and others collect near the top.
  • Calibration gas and a bump test station, because the regulation requires calibrated instruments in good working order. Our guide on bump test vs calibration explains the difference.
  • Personal monitors for entrants, so the air is checked where they're breathing while they work.
A gloved hand holds a yellow portable gas detector over an open manhole before entry, with the legs of a rescue tripod behind it.

2. Ventilation: blowers and ducting

If testing shows a hazard, or the work will create one, the space has to be purged, ventilated or both before entry. A portable blower with ducting brings fresh air in or pulls contaminated air out. Choose an explosion-proof blower and statically conductive ducting where flammable vapours are possible. Place the intake away from vehicle exhaust and generators, and retest after ventilating. Ventilation doesn't replace monitoring.

3. Entry and retrieval: tripod or davit, winch and harness

For a vertical entry such as a manhole or tank hatch, a confined space retrieval system gives a controlled way in and a fast way out:

  • A tripod or davit system rated for the use, set up over the opening. Tripods suit portable work over manholes; davit masts mount to fixed or portable bases where tripods won't fit.
  • A man-rated winch to raise and lower the entrant. Winch-hoist questions often come down to cable length and whether the system is rated for personnel.
  • A 3-way self-retracting lifeline (SRL) with retrieval, which arrests a fall and lets the attendant crank the worker out in an emergency.
  • A retrieval harness with the D-rings the rescue plan calls for, such as a back D-ring or shoulder retrieval loops, so a worker can be lifted upright through a narrow opening.

Keep the line attached whenever it's practical and won't create a snag or entanglement hazard. That's what makes non-entry rescue possible.

4. Communication and the attendant

The attendant stays outside, keeps constant contact and never goes in (O. Reg. 632/05, s. 15). Match the method of communication to the space: voice and sight lines for a shallow pit, hands-free radios or a hard-wired system where distance, noise or steel walls get in the way. The attendant also needs a reliable way to call for rescue. Test it at the start of every entry.

5. PPE for the entrant

PPE depends on the hazard assessment, not the space's name. Common items include a hard hat, eye and face protection, gloves and chemical-resistant clothing for the substances present, hearing protection and safety footwear. Where ventilation can't maintain acceptable air for technical reasons, O. Reg. 632/05 requires adequate respiratory protection and equipment that lets people outside locate and rescue the worker (s. 20(4)). In low-oxygen or unknown atmospheres, that usually means supplied-air respirators, not air-purifying ones.

6. Rescue: plan it, rig it, practise it

Ontario requires written on-site rescue procedures ready for immediate use and enough people trained in them, in first aid and CPR, and in the rescue equipment before anyone enters (s. 11). Plan non-entry rescue first, using the retrieval system already rigged. If rescuers might have to enter, they need their own equipment and training. Calling 911 is not a rescue plan on its own.

Confined space equipment checklist

  • Multi-gas detector bump-tested today and within its calibration date, with sampling pump and tubing
  • Calibration gas and bump test station available
  • Blower and ducting sized for the space (explosion-proof where needed), plus a ventilation-failure warning and exit procedure
  • Tripod or davit, man-rated winch and 3-way SRL with retrieval, inspected and recorded
  • Retrieval harness fitted to each entrant
  • Communication tested between entrant and attendant, plus a way to summon rescue
  • Entrant PPE and any respiratory protection matched to the hazard assessment
  • Barricades or signs to stop unauthorized entry
  • Equipment list and inspection results recorded on the entry permit

Keyline Safety's stand

Equipment doesn't make a confined space safe. A plan does, and the equipment has to match it. Keyline Safety would rather help a crew rig the retrieval system and bump-test the monitor before the lid comes off than see anyone improvise a rescue. If the plan says non-entry rescue, the tripod, winch and harness have to be on site and connected, not on the truck.

What Keyline Safety does

Keyline Safety is a PPE and safety supplier in London, Ontario, serving Canadian workplaces since 1968. For confined space work, our range includes:

Building a confined space kit for your crew? Ask Keyline Safety through our safety assistant chat.

Frequently asked questions

What equipment is needed for confined space entry?

At minimum, a calibrated gas detector, ventilation where testing or the work requires it, a means of entry and exit such as a tripod or davit with a winch, a retrieval harness and lifeline, communication between the entrant and attendant, PPE for the hazards and rescue equipment ready to use.

What is a confined space retrieval system?

It's the set-up that lets an attendant raise a worker out of a space without entering: usually a tripod or davit over the opening, a man-rated winch or 3-way self-retracting lifeline with retrieval, and a harness with retrieval D-rings.

Do I need a tripod for every confined space?

No. Tripods suit vertical openings such as manholes and hatches. Horizontal or side entries may need a davit, side-entry system or other retrieval method. The rescue plan for each space decides what's appropriate.

How often does confined space rescue equipment need to be inspected?

Ontario's O. Reg. 632/05 says as often as necessary to keep it in good working order, by a competent person appointed by the employer, with the inspection recorded. Also follow the manufacturer's inspection schedule and check it before each use.

What oxygen level is acceptable for confined space entry in Ontario?

O. Reg. 632/05 defines acceptable oxygen as at least 19.5% and not more than 23% by volume. Flammable gas and toxic contaminant limits also apply.

Keep reading

Sources

Back to blog

Leave a comment